US18, Sensors

US18

US18

Ultrasonic M18x1 ABS tubular sensors of the US18 series are available in models with axial or radial acoustic emission and with discrete bipolar output (1 NPN and 1 PNP) or with 4-20 mA or 0-10 V analogue output

Features

Distance range 50...500 mm Minimum object 5 mm High resolution to 1 mm or 0.1% of distance range

Standard M18 tubular and M18 right angle mounting

IP67 Neman 6P rated

12…30 Vdc

Ultrasonic 300kHz

M12 connector NPN and PNP switching outputs for object detection 0-10 V or 4-20 mA an out for distance measurement

ASIC

ABS housing

Integral push button or remote TEACH

Overview

Ultrasonic M18 sensors of the US18 series are available in two different barrel housings: tubular and right angle mounting.
M18 Tubular series offers models either with discrete bipolar output (1 NPN and 1 PNP) or with 4-20 mA or 0-10 V analog output, each with axial or radial acoustic emission. M18 Right angle series provides discrete outputs (PNP or NPN).
US18 series guarantees a small blind zone providing a wide operating range from 30 to 300 mm for the tubular models and from 50 to 500 mm for the right angle models. The sensors are easily configured through the Teach-in function, while the operating status is visibly signalled by 2 bi-coloured LEDs.     

Videos and Images

Downloads for US18

US18 Series Datasheet
03/07/2014 - DS-US18-ENA4
(.pdf, 1607513 byte)
03/07/2014 - DS-US18-ENUS
(.pdf, 1088457 byte)
03/07/2014 - DS-US18-IT
(.pdf, 1605573 byte)
22/07/2014 - DS-US18-DE
(.pdf, 1620214 byte)
US18-PL Instruction Manuals
14/07/2015 - US18-PL_ultrasonicsensors_manual_RevB_eng
(.pdf, 249630 byte)
US18-PA/PR ANALOG Instruction Manuals
14/04/2011 - US18-PA/PR Analog ultrasonicsensors manual rev C eng
(.pdf, 143655 byte)
14/04/2011 - US18-PA/PR Analog ultrasonicsensors manual rev C ita
(.pdf, 152256 byte)
US18-PA/PR DIGITAL Instruction Manuals
11/07/2014 - US18-PA_PR Digital_ultrasonicsensors_manual_revD_eng
(.pdf, 140861 byte)
11/07/2014 - US18-PA_PR Digital_ultrasonicsensors_manual_revD_ita
(.pdf, 144620 byte)
WP-PRIMARY_PACKAGING
17/04/2013 - WP-PRIMARY_PACKAGING-ENA4
(.pdf, 1145081 byte)
17/04/2013 - WP-PRIMARY_PACKAGING-DE
(.pdf, 1153696 byte)
Sensors Product Guide
23/06/2016 - PG-Sensors-ENA4
(.pdf, 2848943 byte)
23/06/2016 - Pg-Sensors-ENUS
(.pdf, 2593777 byte)
03/03/2016 - PG-Sensors-DE
(.pdf, 2869618 byte)
23/06/2016 - PG-Sensors-IT
(.pdf, 2901176 byte)
23/06/2016 - PG-Sensors-ZH
(.pdf, 2494620 byte)
US18-PA/PR Drawings
05/04/2013 - US18-PA/PR_ultrasonicsensors_PDF
(.pdf, 97260 byte)
05/04/2013 - US18-PA/PR_ultrasonicsensors_DWG
(.dwg, 1200484 byte)
29/10/2013 - US18-PA_ultrasonicsensors_IGES
(.igs, 3691066 byte)
29/10/2013 - US18-PR_ultrasonicsensors_IGES
(.igs, 3422188 byte)
29/10/2013 - US18-PA_ultrasonicsensors_STEP
(.stp, 3226894 byte)
29/10/2013 - US18-PR_ultrasonicsensors_STEP
(.stp, 2936354 byte)
US18-PL Drawings
07/07/2014 - US18-PL_ultrasonicsensors_PDF
(.pdf, 44492 byte)
07/07/2014 - US18-PL_ultrasonicsensors_DXF
(.dxf, 806346 byte)
07/07/2014 - US18-PL_ultrasonicsensors_IGES
(.igs, 2234336 byte)
07/07/2014 - US18-PL_ultrasonicsensors_STEP
(.stp, 1790421 byte)

Contacts and Success Stories

Contact Us
Contact Us
Contact Us
If you are looking for more information or advice on a particular matter, you’ll find many ways to contact us right here.
Success Stories
Success Stories
Success Stories

RMA and Tech support

Online RMA
Online RMA
Online RMA
All information needed to process an RMA request (Return Material Authorization) including collection service from customers
Tech Support
Tech Support
Tech Support
Whether you’re looking for answers or would like to solve a problem we’ll help you resolve your issues quickly and easily

Service Program

Whenever the Total Cost of Ownership is critical for expense management, Datalogic customers can take advantage of different post-sales service packages following these basics guidelines: fixed costs, fully guaranteed turnaround, different service levels for various needs, different level of support ( from telephone to On Site emergency visit), high professionalism of Datalogic Repair Depots, original Datalogic spare parts, accurate quality control procedures. The Hot SWAP Maintenance Agreement is our 24 hour maintenance program that guarantees that defective products will be substituted within 24 hours of notification.

The Managed CARE program guarantees you repair and return of defective products within 5 days. The PREMIUM Service provides periodical preventive maintenance on your system while the TOTAL Cover Service contract adds on-site intervention by specialised technicians, within 24-48 hours of notification.