Power supply:
10 ... 30 Vdc, reverse polarity protection
Consumption:
30 mA max.
Light emission:
infrared 880 nm LED
red 660 nm LED (B2, D12, E1 vers.)
Diffuse proximity operating distance:
0 ... 10 cm (C10 vers.)
0 ... 50 cm (C50 vers.)
Fixed focus operating distance:
12 mm with 1 mm spot (D12 vers.)
Retroreflex operating distance:
0.1 ... 2.5 m (on R2)
Polarised retroreflex operating
distance:
0.1 ... 2 m (on R2)
Retroreflex for transparents op.
distance:
0.2 ... 0.8 m (on R2)
Through beam operating distance:
0 ... 5 m
Operating distance with fibre-optics:
33 mm proximity (with OF-18-ST)
110 mm through beam (with OF-19-ST)
refer to OF series for other fibres
Setting:
sensitivity trimmer
Indicators:
red OUTPUT LED
green STABILITY LED
red POWER LED (G5 vers.)
Output type:
PNP (connector vers.)
NPN/PNP configurable (cable vers.)
Saturation voltage:
1.5 V max.
Output current:
100 mA max., short-circuit protection
Response time:
1 ms max.
2 ms (F vers.)
Switching frequency:
500 Hz max.
250 Hz max. (F vers.)
Operating mode:
dark/light configurable
Auxiliary functions:
‘test +’ and ‘test -’ inputs (G vers.)
Connection:
M8 4-pole connector
2 m Ø 5 mm cable
Electrical protection:
class 2
Mechanical protection:
IP66
Housing material:
ABS
Lens material:
PMMA plastic
Weight:
20 g max. (connector vers.)
90 g max. (cable vers.)
Operating temperature:
-25 ... +55°C
Storage temperature:
-25 ... +70°C
Reference standard:
EN 60947-5-2
Certifications:
TECHNICAL DATA
DETECTION DIAGRAMS
Grey R18%
R2
R2
Grey R18%
White R90%
White R90%
R5
R5
R2
R5
S3-x-C10-x
S3-x-C50-x
S3-x-A2.5-x
S3-x-B2-x
S3-x-T0.8-x
S3-x-F/G-x
The operating distances indicate the detection distance with excess gain 2.
The detection diagrams indicate the typical operating distance
with excess gain 1.