Power supply:
10 ... 30 Vdc, reverse polarity protection
15 ... 264 Vac/Vdc
Consumption:
30 mA max. (d.c. vers.)
3 VA max. (a.c. vers.)
Light emission:
infrared LED 880 nm
red LED 660 nm (B vers.)
Diffuse proximity operating distan-
ce:
1 ... 90 cm (C90 vers.)
1 ... 200 cm (C200 vers.)
Retroreflex operating distance:
0.1 ... 5 m (on R2)
Polarised retroreflex operating
distance:
0.15 ... 3 m (on R2)
Through beam operating distance:
0 ... 10 m (G10/F10 vers.)
0 ... 50 m (G50/F50 vers.)
Setting:
sensitivity trimmer
Indicators:
red OUTPUT LED
green STABILITY LED
Output type:
NPN and PNP, open collector (d.c. vers.)
or relay 1 NO contact (a.c. vers.)
Saturation voltage:
1 V max. (NPN vers.)
2 V max. (PNP vers.)
Output current:
100 mA max., short-circuit protection
relay 1 A (250 Vac), resistive load
Response time:
1 ms max. (d.c. vers.)
20 ms max. (a.c. vers.)
Switching frequency:
500 Hz max. (d.c. vers.)
25 Hz max. (a.c. vers.)
Timing function:
normal, ON-delay, OFF-delay, ON/OFF-
delay, one-shot all adjustable from 0.6
to 16 sec.
Operating mode:
dark/light selectable
Connection:
terminal block with 4 screw terminals
gland for cables with 8 to 10 mm diameter
Electrical protection:
class 1 (a.c. vers.)
class 2 (d.c. vers.)
Mechanical protection:
IP66
Housing material:
PBT plastic
Lens material:
PMMA plastic
Weight:
100 g max.
Operating temperature:
-25 ... +55°C
Storage temperature:
-25 ... +70°C
Reference standard:
EN 60947-5-2
Certifications:
TECHNICAL DATA
DETECTION DIAGRAMS
UNI EN ISO9001
The detection diagrams indicate the typical operating
distance with excess gain 1.
The operating distances indicate the detection distance with excess
gain 2.
S2-x-C90-x
S2-x-C200-x
S2-x-A5-x
S2-x-B3-x
S2-x-F10/G10
S2-x-F50/G50
Grey R18%
White R90%
Grey R18%
White R90%
R2
R2
R5
R5