Technical Data
TABLES
Model
SG2 height 150
8
SG2 height 300
16
SG2 height 450
24
SG2 height 600
32
SG2 height 750
40
SG2 height 900
48
SG2 height 1050
56
SG2 height 1200
64
SG2 height 1350
72
SG2 height 1500
80
SG2 height 1650
88
SG2 height 1800
96
Table 1: NUMBER OF CONTROLLED BEAMS
Model
SG2 height 150
150
SG2 height 300
300
SG2 height 450
450
SG2 height 600
600
SG2 height 750
750
SG2 height 900
900
SG2 height 1050
1050
SG2 height 1200
1200
SG2 height 1350
1350
SG2 height 1500
1500
SG2 height 1650
1650
SG2 height 1800
1800
Table 2: CONTROLLED HEIGHT (mm)
Model
SG2 height 150
8
SG2 height 300
9
SG2 height 450
11
SG2 height 600
12
SG2 height 750
14
SG2 height 900
15
SG2 height 1050
17
SG2 height 1200
18
SG2 height 1350
20
SG2 height 1500
21
SG2 height 1650
23
SG2 height 1800
24
Table 3: RESPONSE TIME (ms)
*If a longer cable has to be used, please verify that the capacitive load
specifications are respected
Electrical Data
Power supply (Vdd):
24 Vdc ± 20%
Consumption (emitter):
2 W max
Consumption (receiver):
3.5 W max (without load)
OSSD outputs:
2 PNP
Short-circuit protection:
1.4 A max
Output current:
0.5 A max on each output
Output voltage - ON status:
Vdd –1 V min
Output voltage - OFF status:
0.2 V max
Capacitive load:
2.2 uF @ 24 Vdc max
Response time:
Refer to table
Controlled height:
150...1800 mm
Safety category:
Type 2
Auxiliary functions:
SG2-B
Reset / Test
Automatic Restart
SG2-E
Reset / Test
Man./Auto Restart
Selectable EDM
Electrical protection:
Class I / Class III
Connections:
SG2-B
M12 4-pole for emitter
M12 5-pole for receiver
SG2-E
M12 4-pole for emitter
M12 8-pole for receiver
Cable length (for powering):
50 m max *
Optical Data
Light emission:
Infrared LED (950 nm)
Resolution:
30 mm
Operating distance:
0.2…19 m (SG2-B)
selectable 0.2…9 m / 0.2…19 m (SG2-E)
Aperture angle (EAA) :
± 5°
Ambient light rejection:
IEC-61496-2
MECHANICAL AND ENVIRONMENTAL DATA
Operating temperature:
SG2-B
0…+ 55 °C
SG2-E
- 10…+ 55 °C
Storage temperature:
- 25…+ 70 °C
Temperature class:
T6
Humidity:
15…95 % (non condensating)
Mechanical protection:
IP 65 (EN 60529)
Vibrations:
0.35 mm amplitude
ency, 20 sweep per axis
1 octave/min (EN 60068-2-6)
Shock resistance:
16 ms (10 G) 1.000 shock per axis
(EN 60068-2-29)
Housing material:
Painted aluminium (yellow RAL 1003)
Protective shield materiale:
PMMA
Cap material:
PC MAKROLON
Weight:
1 kg / m