TECHNICAL DATA
TECHNICAL NOTES
1
Limit values
2
Average life of 100.000 h with TA = +25 °C
3
PVC, 4 x 0.14 mm
2
4
Compatible with quick connection systems
5
A - reverse polarity protection
B - overload and short-circuit protection on receiver outputs
S50-PA-2-A00-NN
S50-PA-2-A00-PP
S50-PA-5-A00-NN
S50-PA-5-A00-PP
S50-MA-2-A00-NN
S50-MA-2-A00-PP
S50-MA-5-A00-NN
S50-MA-5-A00-PP
Operating distance:
0.1 ... 5 m
● ● ● ● ● ● ● ●
Power supply:
10 ... 30 Vdc
1
● ● ● ● ● ● ● ●
Ripple:
≤ 2 Vpp
● ● ● ● ● ● ● ●
Consumption:
≤ 35 mA
● ● ● ● ● ● ● ●
Light emission:
infrared LED 880 nm
2
● ● ● ● ● ● ● ●
Spot dimension:
approx. 100 mm at 2 m ● ● ● ● ● ● ● ●
Indicators:
yellow OUTPUT LED ● ● ● ● ● ● ● ●
Output type:
PNP, NO and NC
● ● ● ●
NPN, NO and NC ● ● ● ●
Output current:
≤100 mA
● ● ● ● ● ● ● ●
Saturation voltage:
≤2 V
● ● ● ● ● ● ● ●
Response time:
0.5 ms
● ● ● ● ● ● ● ●
Switching frequency:
1 kHz
● ● ● ● ● ● ● ●
Operating mode:
dark on NO / light on NC ● ● ● ● ● ● ● ●
Connection:
2 m Ø 4 mm cable
3
● ●
● ●
M12 4-pole connector
4
● ●
● ●
Electrical protection:
class 2
● ● ● ● ● ● ● ●
Mechanical protection:
IP67
● ● ● ● ● ● ● ●
Protection devices:
A, B
5
● ● ● ● ● ● ● ●
Housing material:
PBT
● ● ● ●
nickel plated brass
● ● ● ●
Lens material:
PMMA
● ● ● ● ● ● ● ●
Weight:
75 g max.
● ●
25 g max.
● ●
110 g max.
● ●
60 g max.
● ●
Operating temperature:
-25 ... +55°C
● ● ● ● ● ● ● ●
Storage temperature:
-25 ... +70°C
● ● ● ● ● ● ● ●
Reference standard:
EN 60947-5-2
● ● ● ● ● ● ● ●
SELECTION TABLE
plastic - axial optics - 2 m cable
S50-PA-2-A00-NN 952002090
NPN
S50-PA-2-A00-PP 952002080
PNP
metal - axial optics - 2 m cable
S50-MA-2-A00-NN 952022090
NPN
S50-MA-2-A00-PP 952022080
PNP
plastic - axial optics - M12 connector
S50-PA-5-A00-NN 952002110
NPN
S50-PA-5-A00-PP 952002100
PNP
metal - axial optics - M12 connector
S50-MA-5-A00-NN 952022110
NPN
S50-MA-5-A00-PP 952022100
PNP
DETECTION DIAGRAMS
All the ordering codes and information are
summarised in the last pages of this catalogue.
Excess gain
Detection area
R5
R2
R2
R5
Operating distance
II3DG