SAFETY LIGH CURTAIN MODEL
CONNECTION BOX MODEL
SG2 BODY COMPACT BASE
-
SG2 BODY COMPACT MUTING
SG-SRT-1
SG4 BODY COMPACT BASE
-
SG4 BODY COMPACT MUTING
SG-SRT-1
SG2 BODY BIG BASE
-
SG2 BODY BIG MUTING
SG-SRT-1 / SG-SRT-2
SG4 BODY BIG BASE
-
SG4 BODY BIG MUTING
SG-SRT-1 / SG-SRT-2
SG4 BODY REFLECTOR BASE
-
SG4 BODY REFLECTOR MUTING
SG-SRT-1 / SG-SRT-2
CONNECTION BOX AND SAFETY LIGHT CURTAIN CORRESPONDENCE
FUNCTIONING
The SG-SRT connection boxes allow you to directly manage, without further action, the following functions according to the typical
operation of the connected Safety Barrier model:
FUNCTION
THROUGH
TEST
TEST/START Push button
RESTART
TEST/START Push button
RESET
TEST/START Push button
EDM internal
Internal Selector
EDM external actuators
Internal Selector
OVERRIDE
Key Selector
MUTING STATE
Integrated Lamp (SG-SRT-2 only)
Please refer to the Safety Barrier Manuals for all information regarding connections, operations and options for the functions listed
above.
MODEL
DESCRIPTION
ORDER N°
SG-SRT-1
SG-SRT-1 MUTING CONNECTION BOX
95ASE2050
SG-SRT-2
SG-SRT-2 MUTING CONNECTION BOX LAMP
95ASE2060
MODEL SELECTION AND ORDER INFORMATION
OUTPUT RELAY BEHAVIOUR
The boxes use 2 safety guided relay contacts. These relays are specified by the manufacturer for higher voltages and currents as
indicated by the technical data.
However, to ensure correct isolation and prevent premature damage for age drift, you need to protect each output line using a delayed
6A fuse and verify that the load characteristics comply with the instructions below:
Max. switchable voltage: 250 Vac
Max. switchable current: 2 A