Long diffuse proximity operating dist.:
1 ... 40 cm (radial version 30 cm)
Short diffuse proximity operating dist.:
0 ... 10 cm (radial version 8 cm)
Narrow beam proximity operating dist.:
0.2…10 cm
Retroreflex operating distance:
0.1…4 m (radial version 3 m) on R5
Polarised retroreflx operating distance:
0.1…3 m (radial version 2.5 m) on R5
Through beam operating distance:
0…20 m (radial version 18 m)
Power supply:
10 ... 30 Vdc
1
Ripple:
≤2 Vpp
Consumption:
≤35 mA
Light emission
2
:
infrared LED 880 nm
red LED 650 nm (B01 mod.)
Setting:
sensitivity trimmer (B01, C01 mod.)
3
Indicators:
yellow OUTPUT LED (excl. G00 mod.)
green POWER LED (G00 mod.)
Output type:
NPN vers. or PNP vers.
Output current:
≤100 mA
Saturation voltage:
≤2 V
Response time:
1 ms
4 ms (F00 mod.)
Switching frequency:
≤500 Hz
≤120 Hz (F00 mod.)
Operating mode:
dark/light selectable
4
Auxiliary functions:
Test + and Test - (G00 mod.)
5
Connection:
2 m Ø 4 mm cable
6
M12 4-pole connector
7
Electrical protection:
class 2
Mechanical protection:
IP67
Protection devices:
A, B
8
Housing material:
PBT (S51-P vers.)
nickel-plated brass (S51-M vers.)
Lens material:
PMMA
Weight:
25 g max. (S51-PA/PR-5 vers.)
75 g max. (S51-PA-/PR-2 vers.)
60 g max. (S51-MA/MR-5 vers.)
100 g max. (S51-MA/MR-2 vers.)
Operating temperature:
-25 ... +55°C
Storage temperature:
-25 ... +70°C
Reference standard:
EN 60947-5-2, UL 508
TECHNICAL DATA
DETECTION DIAGRAMS
Note
: the diagrams indicate the detection area typical of the axial
optic versions; the maximum operating distance of the radial optic
versions decreases as indicated in the tables given below
Grey 18%
White 90%
C01 - long diffuse proximity
Grey 18%
White 90%
C10 - short diffuse proximity
Grey 18%
White 90%
C20 - narrow beam proximity
R2
R5
A00 - retroreflex
R2
R5
B01 - polarised retroreflex
F00/G00 - through beam
TECHNICAL NOTES
1
Limit values
2
Average life of 100.000 h with TA = +25 °C
3
270° single-turn trimmer
4
With L/D input not connected the proximity models function in the light mode and the retrore-
flex and through beam models in the dark mode; the light mode can be selected
connecting the L/D input to +Vdc, the dark mode connecting it to 0Vdc
5
Emitter off with Test+ connected to +Vdc and Test- to 0 Vdc
6
PVC, 4 x 0.14 mm2
7
M12 connector compatible with quick connection systems
8
A - reverse polarity protection
B - overload and short-circuit protection
Recommended operating distance
Maximum operating distance
*Only on axial optic models
II3DG*