TECHNICAL DATA
SELECTION TABLE
DETECTION DIAGRAMS
All the ordering codes and information are
summarised in the last pages of this catalogue.
distance sensor - M12 connector
S60-PA-5-Y03-NV 956201710
PNP
S60-PA-5-Y03-PV 956201700
NPN
TECHNICAL NOTES
1
Measurement field can be reduced at device setting
2
Limit values
3
Average life of 100.000 h with TA = +25 °C
3
Connect to 0 V when remote wire not used
4
PVC, 4 x 0.14 mm
2
5
Connector can be blocked on two positions
6
A - reverse polarity protection
B - overload and short-circuit protection on outputs
7
Internal lenses in Polycarbonate
S60-PA-5-Y03-NV
S60-PA-5-Y03-PV
Operating distance:
60 ... 150 mm
1
● ●
Power supply:
18 ... 30 Vdc
2
● ●
Ripple:
≤2 Vpp
● ●
Consumption:
≤60 mA
● ●
Light emission:
red LED 670 nm
3
● ●
Spot dimensions:
approx. 16 mm at 150 mm
● ●
Setting:
teach-in push-button
● ●
Setting procedure:
EASYtouch™
● ●
Indicators:
yellow OUTPUT LED
● ●
red FIELD LED
● ●
Output type:
PNP, NO
●
NPN, NO
●
analogue with 0 ... 10 V (8 bit)
● ●
Minimum resistance load:
1 KW
● ●
Output current:
≤100 mA
● ●
Saturage voltage:
≤ 2 V
● ●
Response time:
1 ms
● ●
Switching frequency:
500 Hz
● ●
Resolution:
1 mm (linearity ± 2.5 %)
● ●
Operating mode:
light with EASYtouch™ ● ●
automatic dark / light fine acquisition ● ●
configurable direct/inverse proportionality ● ●
Switching output hysterisis:
10 % max.
● ●
Connection:
2 m Ø 4 mm cable
4
M12 4-pole connector
5
● ●
Electrical protection:
class 2
● ●
Mechanical protection:
IP67
● ●
Protection devices:
A, B
6
● ●
Housing material:
ABS
● ●
Lens material:
window in PMMA
7
● ●
Weight:
90 g max.
40 g max.
● ●
Operating temperature:
-25 ... +55°C
● ●
Storage temperature:
-25 ... +70°C
● ●
Reference standard:
EN 60947-5-2
● ●
Analogue output on max. measurement range in
inverse proportionality
Distance
Voltage (V)
Operating distance