TECHNICAL DATA
DETECTION DIAGRAMS
All the ordering codes and information are
summarised in the last pages of this catalogue.
contrast sensor - 2 m cable
S60-PA-2-W08-NH 956201550
NPN
S60-PA-2-W08-PH 956201400
PNP
contrast sensor - M12 connector
S60-PA-5-W08-NH 95621030
NPN
S60-PA-5-W08-PH 95621020
PNP
TECHNICAL NOTES
1
Limit values
2
Average life of 100.000 h with TA = +25 °C
3
Connect to 0 V when remote wire not used
4
270° trimmer
5
PVC, 4 x 0.14 mm
2
6
Connector can be blocked on two positions
7
A - reverse polarity protection
B - overload and short-circuit protection on outputs
8
Internal lenses in glass
S60-PA-5-W08-NH
S60-PA-5-W08-PH
Operating distance:
19 mm
● ●
Max. field of depth:
± 2 mm
● ●
Power supply:
10 ... 30 Vdc
1
● ●
Ripple:
≤ 2 Vpp
● ●
Consumption:
≤30 mA
● ●
Light emission:
white LED 400 - 700 nm
2
● ●
Spot dimension:
aprox. 3.5 mm at 19 mm
● ●
Resolution:
0.5 mm
● ●
Setting:
teach-in push-button
● ●
remote on cable
3
● ●
Setting procedure:
EASYtouch™
● ●
Indicators:
yellow OUTPUT LED
● ●
green / red READY / ERROR LED ● ●
Output type:
PNP, NO
●
NPN, NO
●
Output current:
≤ 100 mA
● ●
Saturation voltage:
≤ 2 V
● ●
Response time:
100 µs
● ●
Max. switching frequency:
5 kHz
● ●
Operating mode:
dark with EASYtouch™ ● ●
automatic dark / light with fine acquisition ● ●
Timing function:
20 ms minimum output ON
● ●
Auxiliary functions:
remote
● ●
keylock
4
● ●
Connection:
2 m Ø 4 mm cable
5
M12 4-pole connector
6
● ●
Electrical protection:
class 2
● ●
Mechanical protection:
IP67
● ●
Protection devices:
A, B
7
● ●
Housing material:
ABS
● ●
Lens materiale:
window in glass (tilted anti-reflection)
8
● ●
Weight:
90 g max.
40 g max.
● ●
Operating temperature:
-25 ... +55°C
● ●
Storage temperature:
-25 ... +70°C
● ●
Reference standard:
EN 60947-5-2
● ●
SELECTION TABLE
Contrast sensor
Distance
Relative received signal
Contrast sensor
mm
Analogic signal %