TECHNICAL DATA
DETECTION DIAGRAMS
All the ordering codes and information are
summarised in the last pages of this catalogue.
Excess gain
Detection area
White 90%
White 90%
Grey 18%
Grey 18%
axial optics - 2 m cable
S60-PA-2-C01-NN 956201470
NPN
S60-PA-2-C01-PP 956201310
PNP
axial optics - M12 connector
S60-PA-5-C01-NN 956201190
NPN
S60-PA-5-C01-PP 956201050
PNP
TECHNICAL NOTES
1
Limit values
2
Average life of 100.000 h with TA = +25 °C
3
270° trimmer
4
PVC, 4 x 0.14 mm
2
5
Connector can be blocked on two positions
6
A - reverse polarity protection
B - overload and short-circuit protection on outputs
7
Internal lenses in Polycarbonate
S60-PA-2-C01-NN
S60-PA-2-C01-PP
S60-PA-5-C01-NN
S60-PA-5-C01-PP
Operating distance:
0 ... 100 cm
● ● ● ●
Power supply:
10 ... 30 Vdc
1
● ● ● ●
Ripple:
≤ 2 Vpp
● ● ● ●
Consumption:
≤40 mA
● ● ● ●
Light emission:
red LED 660 nm
2
● ● ● ●
Spot dimension:
approx. 50 mm at 90 cm ● ● ● ●
Setting:
sensitivity trimme
r 3
● ● ● ●
Indicators:
yellow OUTPUT LED
● ● ● ●
green STABILITY LED
● ● ● ●
Output type:
PNP, NO and NC
● ●
NPN, NO and NC
● ●
Output current:
≤100 mA
● ● ● ●
Saturation voltage:
≤ 2 V
● ● ● ●
Response time:
1 ms
● ● ● ●
Switching frequency:
500 Hz
● ● ● ●
Operating mode:
light on NO / dark on NC
● ● ● ●
Connection:
2 m Ø 4 mm cable
4
● ●
M12 4-pole connector
5
● ●
Electrical protection:
class 2
● ● ● ●
Mechanical protection:
IP67
● ● ● ●
Protection devices:
A, B
6
● ● ● ●
Housing material:
ABS
● ● ● ●
Lens material:
window in PMMA
7
● ● ● ●
Weight:
90 g max.
● ●
40 g max.
● ●
Operating temperature:
-25 ... +55°C
● ● ● ●
Storage temperature:
-25 ... +70°C
● ● ● ●
Reference standard:
EN 60947-5-2
● ● ● ●
Recommended operating distance
Maximum operating distance
SELECTION TABLE