TECHNICAL DATA
SELECTION TABLE
DETECTION DIAGRAMS
Operating distance
axial optics - 2 m cable
S60-PL-2-B01-NN 956201560
NPN
S60-PL-2-B01-PP 956201410
PNP
axial optics - M12 connector
S60-PL-5-B01-NN 956201260
NPN
S60-PL-5-B01-PP 956201120
PNP
TECHNICAL NOTES
1
Limit values
2
Average life of 100.000 h with TA = +25 °C
3
270° trimmer
4
PVC, 4 x 0.14 mm
2
5
Connector can be blocked on two positions
6
A - reverse polarity protection
B - overload and short-circuit protection on outputs
7
Internal lenses in glass and Polycarbonate
S60-PL-2-B01-NN
S60-PL-2-B01-PP
S60-PL-5-B01-NN
S60-PL-5-B01-PP
Operating distance:
0.1 ... 20 m
● ● ● ●
Power supply:
10 ... 30 Vdc
1
● ● ● ●
Ripple:
≤ 2 Vpp
● ● ● ●
Consumption:
≤ 35 mA
● ● ● ●
Light emission:
red Laser 650 nm
2
● ● ● ●
class 1 EN 60825-1
● ● ● ●
class II CDRH21 CFR 1040.10 ● ● ● ●
Resolution:
approx. 10 mm
● ● ● ●
Setting:
sensitivity trimmer
3
● ● ● ●
Indicators:
yellow OUTPUT LED
● ● ● ●
green POWER ON LED
● ● ● ●
Output type:
PNP, NO and NC
● ●
NPN, NO and NC
● ●
Output current:
≤ 100 mA
● ● ● ●
Saturation voltage:
≤ 2 V
● ● ● ●
Response time:
250 ms
● ● ● ●
Switching frequency:
2 kHz
● ● ● ●
Operating mode:
dark on NO / light on NC
● ● ● ●
Connection:
2 m Ø 4 mm cable
4
● ●
M12 4-pole connector
5
● ●
Electrical protection:
class 2
● ● ● ●
Mechanical protection:
IP67
● ● ● ●
Protection devices:
A, B
6
● ● ● ●
Housing material:
ABS
● ● ● ●
Lens material:
window in PMMA
● ● ● ●
Weight:
90 g max.
● ●
40 g max.
● ●
Operating temperature:
-10 ... +50°C
● ● ● ●
Storage temperature:
-25 ... +70°C
● ● ● ●
Standard reference:
EN 60947-5-2, EN 60825-1,
● ● ● ●
CDRH21 CFR 1040.10
● ● ● ●
All the ordering codes and information are
summarised in the last pages of this catalogue.
Detection area
Resolution on R7 reflector
R5
R7
High efficiency reflectors can be used to
obtain larger operating distances.
Refer to
Reflectors
(A.01) of the