External diameter (sheath)
Ø 2.2 mm
Ø 1 mm (-TN vers.)
Internal diameter (core)
Ø 1 mm
Ø 1.5 mm (-HP vers.)
Ø 0.5 mm (-TN vers.)
Bending radius
25 mm
15 mm (-TN vers.)
5 mm (-XF vers.)
2 mm (-UF vers.)
Normalised efficiency
refer to table 1
Mechanical protection
IP67
Core material
PMMA plastic
Sheath material
PE plastic
Terminal material
nickel-plated brass
Operating temperature
-40 ... +60°C
-40 ... +125°C (-HT vers.)
Storage temperature
-40 ... +60°C
-40 ... +125°C (-HT vers.)
TECHNICAL DATA
TABLE
Table 1: NORMALISED EFFICIENCY *
Fibre type
Code
Efficiency
standard
-ST-
100%
high-temperature
-HT-
70%
extra-flexible
-XF-
90%
ultra-flexible
-UF-
90%
high-efficiency
-HP-
125%
coiled cable
-CL-
65%
thin cable
-TN-
35%
ACCESSORIES
The operating distance is obtained multiplying the normalised
efficiency value by the distance indicated for each sensor with
standard fibre-optics.
AF-1
2 pcs 90° deviating lenses
Gain: distance x 0.7
Suitable fibres: OF-43-xx
Suitable fibres: OF-xx-TN
Suitable fibres: OF-43-xx
Suitable fibres: OF-42-xx
Suitable fibres: all
AF-2
2 pcs collimating lenses
Gain: distance x 4
Suitable fibres: OF-43-xx
AF-3
1 pc focusing lenses
with 4 mm resolution
Operating distance: 19 ± 2 mm
Suitable fibres: OF-44-xx
AF-4
1 pc focusing lenses
with 0.4 mm resolution
Operating distance: 7 ± 1 mm
Suitable fibres: OF-44-xx
AF-9
1 pc metal sheath for M4 x 0.7 fibres
Material: stainless steel
AF-11
Fibre-cutting tool with Ø 2.2 mm and Ø 1.1 mm holes
Material: plastic with stainless steel blade
AF-5
2 pcs adapters Ø2.2mm for thin fibres Ø1mm
Material: plastic
AF-7
1 pc metal sheath for M6 x 0.75 fibres
Material: stainless steel
mm
1...,260,261,262,263,264,265,266,267,268,269 271,272,273,274,275,276,277,278,279,280,...572