Technical Data
Electrical Data
Power supply ( Vdd )
24 Vdc ± 20%
Consumption (TX):
2.5 W max
Consumption (RX):
4 W max (without load)
OSSD outputs:
2 PNP
Short-circuit protection:
1.4 A max
Output current:
0.5 A max on each output
Output voltage – ON status:
Vdd-1 V
Output voltage – OFF status:
0.2 V
Leakage current:
< 1mA
Capacitive load:
2.2 uF @ 24Vdc (*)
Response time:
Refer to table
Controlled height:
150 ... 1800 mm
Safety category:
Type 4
Auxiliary functions:
Reset/Test
Selectable Man./ Auto. Restart
Selectable EDM
Electrical protection:
Class I / Class III
Connections:
M12 4-pole for emitter
M12 8-pole for receiver
Cable length (for powering)
50 m. max (*)
Optical Data
Light emission:
Infrared LED (950 nm)
Resolution:
30 mm
Operating distance:
0.2…19 m
Aperture angle (EAA):
±2.5° max.
Ambient light rejection:
IEC 61496-2
Mechanical and environmental data
Operating temperature:
0…55°C
Storage temperature:
-25…+ 70 °C
Temperature class:
T6
Humidity:
15…95 % (non condensating)
Mechanical protection:
IP65 (EN 60529)
Vibrations:
Width 0.35 mm
Frequency 10 … 55 Hz 20 sweep per axis,
1 octave/min (EN 60068-2-6)
Shock resistance:
16 ms (10g) 1.000 shock per axis
(EN 60068-2-29)
Housing material:
Painted aluminium (yellow RAL 1003)
Protective shield material:
PMMA
Cap material:
PC MAKROLON
Weight:
1.3 Kg / m
TABLES
mODEL
SG4 height 150
8
SG4 height 300
16
SG4 height 450
24
SG4 height 600
32
SG4 height 750
40
SG4 height 900
48
SG4 height 1050
56
SG4 height 1200
64
SG4 height 1350
72
SG4 height 1500
80
SG4 height 1650
88
SG4 height 1800
96
Table 1: NUMBER OF CONTROLLED BEAMS
mODEL
SG4 height 150
150
SG4 height 300
300
SG4 height 450
450
SG4 height 600
600
SG4 height 750
750
SG4 height 900
900
SG4 height 1050
1050
SG4 height 1200
1200
SG4 height 1350
1350
SG4 height 1500
1500
SG4 height 1650
1650
SG4 height 1800
1800
Table 2: CONTROLLED HEIGHT (mm)
mODEL
SG4 height 150
9
SG4 height 300
11
SG4 height 450
13
SG4 height 600
14
SG4 height 750
16
SG4 height 900
18
SG4 height 1050
19
SG4 height 1200
21
SG4 height 1350
23
SG4 height 1500
25
SG4 height 1650
26
SG4 height 1800
28
Table 3: RESPONSE TIME (ms)
*If a longer cable has to be used, please verify that the capacitive load
specifications are respected
1...,418,419,420,421,422,423,424,425,426,427 429,430,431,432,433,434,435,436,437,438,...572