DIMENSIONS
reliability data
mm
CONNECTIONS
rx: m12 8-pole connector
tx: m12 4-pole connector
PL (Ref. EN ISO 13849-1)
d
CAT (Ref. EN 954-1)
2
SIL (Ref. EN IEC 61508)
2
SIL CL (Ref. EN IEC 62061)
2
PFHD – Probability of Danger Failure (1/h)
1,37E-08
T1 – Life Time (Years)
20
MTTFD - Mean Time to Danger Failure (Years)
309
DC – Diagnostic Coverage (%)
96,3%
SFF – Safe Failure Fraction (%)
97,83%
HFT – Hardware Fault Tolerance
0
VERSIONS
L
1
L
2
SE2-P2-050-PP-W 652
543
SE2-P3-080-PP-W 952
843
SE2-P4-090-PP-W 1052
943
SE2-P4-120-PP-W 1352
1243
NC