DIMENSIONS
reliability data
mm
CONNECTIONS
PL (Ref. EN ISO 13849-1)
e
CAT (Ref. EN 954-1)
4
SIL (Ref. EN IEC 61508)
3
SIL CL (Ref. EN IEC 62061)
3
PFHD – Probability of Danger Failure (1/h)
2.76E-09
T1 – Life Time (Years)
20
MTTFD - Mean Time to Danger Failure (Years)
335
DC – Diagnostic Coverage (%)
99,00%
SFF – Safe Failure Fraction (%)
99,44%
HFT – Hardware Fault Tolerance
1
VERSIONS
L
1
L
2
SE4-xx-015-PP-W 256
147
SE4-xx-030-PP-W 403
294
SE4-xx-045-PP-W 550
441
SE4-xx-060-PP-W 697
588
SE4-xx-075-PP-W 844
735
SE4-xx-090-PP-W 991
882
SE4-xx-105-PP-W 1138
1029
SE4-xx-120-PP-W 1285
1176
SE4-xx-135-PP-W 1432
1323
SE4-xx-150-PP-W 1579
1470
rx: m12 8-pole connector
tx: m12 4-pole connector
NC