DIMENSIONS
reliability data
mm
CONNECTIONS
PL (Ref. EN ISO 13849-1)
e
CAT (Ref. EN 954-1)
4
SIL (Ref. EN IEC 61508)
3
SIL CL (Ref. EN IEC 62061)
3
PFHD – Probability of Danger Failure (1/h)
2,76E-09
T1 – Life Time (Years)
20
MTTFD - Mean Time to Danger Failure (Years)
335
DC – Diagnostic Coverage (%)
99%
SFF – Safe Failure Fraction (%)
99,4%
HFT – Hardware Fault Tolerance
1
VERSIONS
L
1
L
2
SE4-x2-050-PP-W 652
543
SE4-x3-080-PP-W 952
853
SE4-x4-090-PP-W 1052
943
SE4-x4-120-PP-W 1352
1243
rx: m12 8-pole connector
tx: m12 4-pole connector
NC
1...,439,440,441,442,443,444,445,446,447,448 450,451,452,453,454,455,456,457,458,459,...572