DIMENSIONS
mm
VERSIONS
L
1
L
2
SE4-xx-015-PP-y 256
147
SE4-xx-030-PP-y 403
294
SE4-xx-045-PP-y 550
441
SE4-xx-060-PP-y 697
588
SE4-xx-075-PP-y 844
735
SE4-xx-090-PP-y 991
882
SE4-xx-105-PP-y 1138
1029
SE4-xx-120-PP-y 1285
1176
model
emitter Receiver
EMD+Blanking M12 4-pole
M12 8-pole
EDM+Cascade
(Master)*
M12 4-pole
+M12 5-pole
M12 8-pole
+M12 5-pole
EDM+Cascade
(Slave)
M12 5-pole M12 5-pole
EDM + Cascade +
Blanking (Master)*
M12 4-pole
+M12 5-pole
M12 8-pole
+M12 5-pole
* an electric terminal is supplied for the Master
Cascade models for the M12 5-pole connection in
order to use the Master unit without connecting the
Slave unit
The features introduced by the safety
light curtains of the SE4-PLUS FINGER
series are given below:
- EDM function: allows to verify the
status of the external monitoring
devices (typically safety relays),
avoiding external malfunctions
jeopardising correct device
functioning.
- Fixed Blanking: allows the operator to
exclude the control of beams in a pre-
set position.
- Floating Blanking: allows the operator
to exclude the control of a pre-set
number of beams in any position
within the detection area.
- Cascade configuration: a couple of
light curtains can function connected
to each other in accordance to a
Master-Slave protocol and combining
the safety information relative to the
two different sections of the controlled
machine. The Master unit has a
Blanking function and can be used
without the Slave unit.
Models with the Muting function are not
available in the SE4-PLUS FINGER
series.
CONNECTIONS
1 = brown = +24 Vdc
2 = white = LINE A
3 = blue = 0 V
4 = black = LINE B
5 = grey = SHIELD
LINE A
LINE B
+24 Vdc
0 V
SHIELD
M12 CONNECTOR
5-POLE
1 = brown = +24 Vdc
2 = white = N.C.
3 = blue = 0 V
4 = black = N.C.
N.C.
N.C.
+24 Vdc
0 V
M12 CONNECTOR
4-POLE
1 = white = TEST/START
2 = brown = +24 Vdc
3 = green = TEACH-IN
4 = yellow = EDM
5 = grey = OSSD1
6 = pink = OSSD2
7 = blue = 0 V
8 = red = BLANKING
TOLERANCE
OSSD1 PNP
Blanking tolerance
OSSD2 PNP
0 V
+24 Vdc
TEST
+24 Vdc
EDM
+24 Vdc
+24 Vdc
Teach-in
N.C. external contact
M12 CONNECTOR
8-POLE
xx= 14 o 30
y: B= BLANKING, M= MASTER, N= MASTER BLANKING, S= SLAVE