TECHNICAL DATA
Power supply:
24 Vdc ± 20% (SELV / PELV)
Consumption:
55 mA max. / 1.5. W (emitter)
125 mA max. / 3.75 W (receiver without load)
Light emission:
infrared LED 880 nm
Number of controlled beams:
refer to table 1
Optic interaxis:
7 mm
Resolution:
14 mm
Controlled height:
refer to table 2
Through beam operating distance:
0.2 ... 6 m
Receiver indicators:
green / red SAFE/ BREAK LED
2 yellow ALIGNMENT LEDs
green POWER ON LED
Emitter indicators:
yellow blinking FAILURE LED
greeen POWER ON LED
Output type:
2 PNP
Output current:
0.5 A max., short-circuit protection
Response time:
refer to tables 3 and 4
Selectable functions:
refer dip-switches
Receiver connection:
refer to connections
Emitter connection:
refer to connections
Cable length:
50 m max. (with 50 nF capacitive load)
Safety category:
Type 4
Electrical protection:
class 1
Mechanical protection:
IP65
Housing material:
aluminium with PC Makrolon plastic caps
Weight:
1.2 Kg max. / m of total height
Operating temperature:
-10 ... +55 °C
Storage temperature:
-25 ... +70 °C
Reference standards:
EN 954-1, IEC 61496-1, IEC 61496-2
MODEL
BEAMS
SE4 height 150
21
SE4 height 300
42
SE4 height 450
63
SE4 height 600
84
SE4 height 750
105
SE4 height 900
126
SE4 height 1050
147
SE4 height 1200
168
Table 1: NUMBER OF BEAMS
MODEL
mm
SE4 height 150
161
SE4 height 300
308
SE4 height 450
455
SE4 height 600
602
SE4 height 750
749
SE4 height 900
896
SE4 height 1050
1043
SE4 height 1200
1190
Table 2: CONTROLLED HEIGHT
MODEL
ms
SE4 height 150
21
SE4 height 300
28
SE4 height 450
35
SE4 height 600
41
SE4 height 750
48
SE4 height 900
55
SE4 height 1050
62
SE4 height 1200
68
Table 3: RESPONSE TIME
DIP1 DIP2 FUNCTION
ON ON Floating function deactivated,
ON OFF Floating function active,
1 Blanking beam
OFF ON Floating function active,
2 adjiacent Blanking beams
OFF OFF Floating function active,
1, 2 or 3 adjacent Blanking beams
SELECTION TABLE
DIP-SWITCHES
1 - Floating function: refer to table
2 - Floating function: refer to table
3 - EDM inactive (ON) / EDM active (OFF)
4 - Automatic (ON) / manual (OFF) reset
1 2 3 4
on
off
FUNCTIONING MODE
Example of
‘Fixed Blanking’
Example of
‘Floating Blanking’
Example of
‘Cascade’ configuration