SG2-M
SG4-E
PL (Ref. EN ISO 13849-1)
d
e
CAT (Ref. EN 954-1)
2
4
SIL (Ref. EN IEC 61508)
2
3
SIL CL (Ref. EN IEC 62061)
2
3
PFHD – Probability of Danger Failure (1/h)
1,04E-08
2,64E-09
T1 – Life Time (Years)
20
20
MTTFD - Mean Time to Danger Failure (Years)
273
444
DC – Diagnostic Coverage (%)
97,50%
98,80%
SFF – Safe Failure Fraction (%)
98,40%
99,30%
HFT – Hardware Fault Tolerance
0
1
RELIABILITY PARAMETERS
MODEL SELECTION TABLE
Description
Protected
height [mm]
Beams
N
.
Response time
[msec]
Resolution
[mm]
Code
SG2-30-030-OO-W
300
16
13
30
957801700
SG2-30-045-OO-W
450
24
14
30
957801710
SG2-30-060-OO-W
600
32
15
30
957801720
SG2-30-075-OO-W
750
40
16
30
957801730
SG2-30-090-OO-W
900
48
17
30
957801740
SG2-30-105-OO-W 1050
56
18
30
957801750
SG2-30-120-OO-W 1200
64
19
30
957801760
SG2-30-135-OO-W 1350
72
19
30
957801770
SG2-30-150-OO-W 1500
80
20
30
957801780
SG2-30-165-OO-W 1650
88
21
30
957801790
SG2-30-180-OO-W 1800
96
22
30
957801800
SG2-M
Description Protected height
[mm]
Beams
N
.
Response time
[msec]
Response time
with code
(msec)
Resolution
[mm]
Code
SG4-14-030-OO-P
300
32
15
20
14
957901240
SG4-14-045-OO-P
450
48
17
25
14
957901250
SG4-14-060-OO-P
600
64
19
29
14
957901260
SG4-14-075-OO-P
750
80
20
34
14
957901270
SG4-14-090-OO-P
900
96
22
38
14
957901280
SG4-14-105-OO-P 1050
112
24
43
14
957901290
SG4-14-120-OO-P 1200
128
26
47
14
957901300
SG4-14-135-OO-P 1350
144
27
52
14
957901310
SG4-14-150-OO-P 1500
160
29
56
14
957901320
SG4-14-165-OO-P 1650
176
31
61
14
957901330
SG4-14-180-OO-P 1800
192
33
65
14
957901340
SG4-E 14