FUNCTIONS - MUTING
Control
Functioning
ACM Configuration
Muting direction
The DEVICE can be used
with both bidirectional ‘T’ or
unidirectional ‘L’ type muting.
Muting Activation Time
T12
Time T12 needed from Muting 1
and Muting 2 signals activation
for starting the Muting.
Values: from 1 to 16 secs
L Muting Deactivation
Time TMoff
When Muitng 1 signal becomes
OFF the device starts a
countdown before stopping the
muting. This countdown lasts
a time related to the Muting
Activation Time T12 by a
multiplier.
Values: from 1 to 16
Muting duration
(Muting TimeOut)
Muting timeout is a time that
defines the maximum duration
of muting function; after the
timeout the muting ends.
Values: from 10 to 1080 min
infinitive (∞)
Muting Filter
The muting filter is a filter on
muting inputs; low-high or
high-low transitions of MUTING
signals are considered valid
only if maintained for a time (Tf)
greater than 100 msec.
Values: ON (100 msec) or
OFF
Override Mode
It’s possible to configure the
trigger of override inputs: Level
or Edge.
Values: LEVEL or EDGE
Override Timeout
Override timeout is the
maximum duration of override.
Values: from 1 to 256 min
Override Restart
This kind of selection can be
achieved only if the light curtain
is in Manual Restart; the user
can select the type of Override
Restart.
Values: Normal or Auto
In this section are listed all the functionalities related with MUTING that can be selected through SG4-E GUI. For detailed explanation
of each function and corresponding Time Diagrams please refer to Instruction manual and GUI software HELP.