This feature can be achieved both through BCM and ACM.
BCM:
press and keep pressed CONFIRM button for
at least 9 sec but less than 30 sec. otherwise the light
curtin goes in lockout failure.
ACM:
press ERASE CONFIGURATION Button on
Device Selection section of GUI after a connected device
has been selected
NOTE: Factory reset will erase both BCM and ACM configurations.
FUNCTIONS - CASCADE
Reduced Resolution
Reduced Resolution is a particular kind of floating blanking in which more than one object can intercept each a defined number of
beams with the device remaining in normal operation.
SG4-E allows to connect in a cascade configuration up to 3 units (1 Master and 2 Slaves). It means a maximum of 160 beams for
30 mm resolution models and a maximum of 320 beams for 14mm resolution models. The maximum length of the master unit is
1800mm and the maximum length of each slave is 1200mm.
Response Time
Please Refer to SG4-E CASCADE RESPONSE TIME section
of this document.
MASTER and SLAVE configuration
A safe auto-recognition procedure at startup is implemented;
it automatically detects cascade topology and correctly
address units.
In order to allow auto-recognition it’s mandatory to connect
the termination cap (supplied on kit) on the tail connector of
last cascade unit, in both transmitter and receiver units.
RESET to FACTORY SETTINGS