TECHNICAL DATA
Power supply:
24 Vdc ± 20% (SELV / PELV)
Consumption:
55 mA max. / 1.5. W (emitter)
125 mA max. / 3.75 W (receiver without load)
Light emission:
infrared LED 880 nm
Number of controlled beams:
refer to table 1
Optic interaxis:
18.4 mm
Resolution:
30 mm
Controlled height:
refer to table 2
Through beam operating distance:
0.2 ... 15 m
Receiver indicators:
green / red SAFE/ BREAK LED
2 yellow ALIGNMENT LEDs
green POWER ON LED
Emitter indicators:
yellow blinking FAILURE LED
greeen POWER ON LED
Output type:
2 PNP
Output current:
0.5 A max., short-circuit protection
Response time:
refer to tables 3 and 4
Selectable functions:
refer dip-switches
Receiver connection:
refer to connections
Emitter connection:
refer to connections
Cable length:
50 m max. (with 50 nF capacitive load)
Safety category:
Type 4
Electrical protection:
class 1
Mechanical protection:
IP65
Housing material:
aluminium with PC Makrolon plastic caps
Weight:
1.2 Kg max. / m of total height
Operating temperature:
-10 ... +55 °C
Storage temperature:
-25 ... +70 °C
Reference standards:
EN 954-1, IEC 61496-1, IEC 61496-2
MODEL
BEAMS
SE4 height150
8
SE4 height 300
16
SE4 height 450
24
SE4 height 600
32
SE4 height 750
40
SE4 height 900
48
SE4 height 1050
56
SE4 height 1200
64
SE4 height 1350
72
SE4 height 1500
80
SE4 height 1650
88
Table 1: NUMBER OF BEAMS
MODEL
mm
SE4 height 150
180
SE4 height 300
327
SE4 height 450
474
SE4 height 600
621
SE4 height 750
768
SE4 height 900
915
SE4 height 1050
1062
SE4 height 1200
1209
SE4 height 1350
1356
SE4 height 1500
1503
SE4 height 1650
1650
Table 2: CONTROLLED HEIGHT
MODEL
ms
SE4 height 150
16
SE4 height 300
20
SE4 height 450
23
SE4 height 600
25
SE4 height 750
27
SE4 height 900
30
SE4 height 1050
32
SE4 height 1200
35
SE4 height 1350
38
SE4 height 1500
40
SE4 height 1650
43
Table 4: RESPONSE TIME
DIP1 DIP2 FUNCTION
ON ON Floating function deactivated,
ON OFF Floating function active,
1 Blanking beam
OFF ON Floating function active,
2 adjiacent Blanking beams
OFF OFF Floating function active,
1, 2 or 3 adjacent Blanking beams
SELECTION TABLE
DIP-SWITCHES
1 - Floating function: refer to table
2 - Floating function: refer to table
3 - EDM inactive (ON) / EDM active (OFF)
4 - Automatic (ON) / manual (OFF) reset
1 2 3 4
on
off
FUNCTIONING MODE
Example of
‘Fixed Blanking’
Example of
‘Floating Blanking’
Example of
‘Cascade’ configuration