Power supply:
24 Vdc ± 20%, (SELV/PELV)
Consumption:
70 mA max. / 2.1 W (emitter)
100 mA max. / 3 W (receiver without load)
Light emission:
infrared LED 880 nm
Optic diameter:
Ø 14 mm
Number of controlled beams:
refer to table 1
Optic interaxis:
7 mm
Resolution:
14 mm
Controlled height:
refer to table 2
Through beam operating distance:
0.2 ... 6 m
Receiver inputs:
external switches for Muting, Test, Restart and
Override
Receiver indicators:
green / red SAFE / BREAK LED
2 yellow ALIGNMENT LEDs
green POWER ON LED
Emitter indicators:
yellow blinking FAILURE LED
green POWER ON LED
Output type:
2 PNP
Output current:
0.7 A max.
0.25 A max. (45°C - 55°C)
short-circuit signalling and protection
Response time:
refer to table 3
Selectable functions:
Total / partial Muting
Manual / Automatic Restart
refer to table 4
Time-out periods:
Muting: 10 minutes
Override: 2 minutes
Muting signalling lamp:
24 V
3 W min. (125 mA), 7 W max. (300 mA)
Receiver connection:
8-pole M12 connector
Emitter connection:
4-pole M12 connector
Cable length:
50 m max. (with 50 nF capacitive load)
Safety category:
type 4
Electrical protection:
class 1
Mechanical protection:
IP65
IP67 (connector part)
Housing material:
aluminium with PC Makrolon plastic caps
Weight:
1.2 Kg max. / m of total height
Operating temperature:
-10 ... +55 °C
Storage temperature:
-25 ... +70 °C
Reference standards:
EN 954-1, IEC 61496-1, IEC 61496-2
TECHNICAL DATA
UNI EN ISO9001
TABLES
Table 4: DIP-SWITCH SELECTION
Model
Beams
SE4 height 150
21
SE4 height 300
42
SE4 height 450
63
SE4 height 600
84
SE4 height 750
105
SE4 height 900
126
Table 1: NUMBER OF BEAMS
Model
mm
SE4 height 150
161
SE4 height 300
308
SE4 height 450
455
SE4 height 600
602
SE4 height 750
749
SE4 height 900
896
Table 2: CONTROLLED HEIGHT
Model
ms
SE4 height 150
18
SE4 height 300
22
SE4 height 450
26
SE4 height 600
31
SE4 height 750
35
SE4 height 900
39
Table 3: RESPONSE TIME
GREY
dip-switches: total / partial Muting selection
WHITE
dip-switches: manual / auto. Restart selection