models
technical data
MODEL
DESCRIPTION
ORDER N°
CS ME-03VU24-Y14
EDM RELAY BOX
95ASE1270
The company endeavours to continuously improve and renew its products; for this reason the technical data and contents of this catalogue may undergo
variations without prior notice. For correct installation and use, the company can guarantee only the data indicated in the instruction manual supplied with the
products.
* Data type approved by UL conforms to the standard UL 508 (f le E131787)
Notes (data type approved by UL):
- Use 60° or 75 °C copper (Cu) conductor and wire size No. 30-12 AWG.
- The terminal tightening torque of 5-7 Lb-In.
- Only for 24 VAC/DC version, supply from remote class 2 source or limited voltage and limited energy.
UNI EN ISO9001
HOUSING
Material:
Polyamide PA 6.6 class V0 (UL94)
Protection degree:
IP40 (housing) IP20 (terminal block)
Dimensions (L x H x D):
111.5 x 99.0 x 22.5mm
Cable cross section:
0.2 … 2.5mm2 24 … 12AWG
Terminal driving torque:
0.5 … 0.6Nm
GENERAL FEATURES
Safety category:
up to category 4 according to EN 954-1 (dependent from the base module)
Ambient temperature:
-25 … + 55°C
Mechanical endurance:
> 10 millions operations
Electrical endurance:
> 100.000 operations
Pollution degree:
outside 3, inside 2
Pulse withstand voltage (Uimp):
2.5KV
Rated insulation voltage:
250V
Over-voltage category:
II
Insulation type:
basic insulation
Weight:
0.2Kg
POWER SUPPLY
Rated operating voltage (Un):
24Vdc*
Max residual ripple in DC:
10%
Supply voltage tolerance:
±20% di Un
Rated power consumption DC:
< 2W*
Start power consumption:
< 3W control circuit
CONTROL CIRCUIT
Operating time tA:
40ms
Releasing time on de-energisation tR1:
15ms + output circuit
OUTPUT CIRCUIT
Output contacts:
3 NO safety contacts
1 NC feedback contact
Contact type:
forced guided contacts
Contacts material:
Silver alloy, gold plated
Max. switching voltage:
230 */240Vac; 300Vdc
Max. switching current per contact:
6A*
Simoltaneous currents sum of 3 outputs:
≤ 12A
Conventional free air thermal current:
6A
Contacts resistance:
≤100mW
Protection fuse outside:
6A*
Max. switching capacity:
1380 A/W
Utilization category (EN 60947-5-1):
AC15, Ue= 230V, Ie= 3 A DC13, Ue= 24V, Ie= 6 A (6 operations/minute)
Utilization category (UL508):
C300
STANDARD CONFORMITY
Standard conformity:
EN 60204-1, EN 954, EN 999, EN 1037, EN ISO 12100-1, EN ISO 12100-2, EN 418, EN 60529,
EN 61000-6-2, EN 61000-6-3, EN 62326-1, EN 60664-1, EN 60947-1, UL 508, CSA C22.2 n°14-
95
Directory conformity:
2006/95/EC, 2006/42/EC, 2004/108/EC
Clearance and creepage distances:
according to EN 60947-1
Approvals:
UL file n° E131787