SL5…SG-ST4
S5…SG-ST2/ST4
Power supply:
24 Vdc ±15%
Consumption (excluded output current):
35 mA max.
30 mA max.
Outputs:
PNP (short-circtuit protection)
Output current:
100 mA max.
Output saturation voltage:
2 V max.
Leakage current:
50 μA at 30 Vdc
Response time:
1 ms max.
Switching frequency:
500 Hz max.
Operating temperature:
-10 … 50 °C
-25 … 55 °C
Storage temperature:
-25 … 70 °C
Dialectric strength:
500 Vac / 1 min. between electronic parts and housing
Insulating resistance
>20 MΩ / 500 Vdc, between electronic parts and housing
Operating distance (min. values):
0 … 40 m
0…8 m
Emission type:
red Laser (650 nm)
Class 1 EN 60825-1 (1994)
LED infrared 880 nm
Effective aperture angle:
xx…ST2 = ± 5° / xx…ST4 = ± 2.5°
Ambient light rejection:
according to EN 60947-5-2
Vibration:
0.5 mm amplitude, 10 … 55 Hz frequency, for each axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shocks for each axis (EN60068-2-27)
Housing material:
ABS UL 94V-O
Connector/gland material:
Polycarbonate
Lens material:
PMMA
Mechanical protection:
IP67
Connections:
M12 4-pole connector
Weight:
30 g. max.
DC MODELS
S300…2/5-G/F-ST2/ST4
Power supply:
24 VDC ±15%
Ripple:
10 % max
Consumption (excluded output current):
S300…F: <25mA
S300…G: < 20 mA
Outputs:
PNP NC open collector
Output current:
100 mA (resistive load)
Output saturation voltage:
2.4 V max
Diagnostic functions
Test- iput
Response time:
1 ms
Switching frequency:
500 Hz
Weight:
140 g
Common data
S300…G
S300…F
Emission type:
INFRARED LED (880nm)
Operating distance (typical value):
S300…ST2: 0..50m
S300…ST4: 0..40m
EAA:
S300…ST2: ± 5° / S300…ST4: ±2.5°
Indicators:
POWER ON LED (GREEN)
OUTPUT LED (YELLOW),
STABILITY LED (GREEN)
Operating temperature:
-40…55 °C
Storage temperature:
-40…70 °C
Insulating resistance:
> 20 MΏ, 500 VDC between electronics and housing
Ambient light rejection:
EN 60947-5-2
Vibration:
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Housing:
PBT 30% Glass fiber-reiforced
Lenses:
frontal window and lens in PC
Protection class:
IP67 (IEC / EN60529) / cable gland EN50262
UL requirements:
Class 2 power supply; 60-70°C copper conductor 24-20 AWG; Type 1 Enclosure
Connections:
see the “CONNECTIONS” paragraph
TECHNICAL DATA
S5/SL5