SG-BWS-T4 CONNECTIONS
NOTE : As SG-BWS-T4 has OSSD Safety outputs in order to have relay outputs, the device must have EDM function connected to the
CS-ME EDM relay box as represented below:
SIGNAL
CONTACT
CONNECTION
VCC
1
External 24Vdc
START/TEST/RESET
2
- Contact NC towards 24Vdc
EDM ENABLE
3
- 24Vdc > EDM DEACTIVATED
- Not connected > EDM activated
EDM
4
- NC contact of external relays towards 24Vdc (with EDM activated)
- Not connected > with EDM deactivated
0V
5
External 0Vdc
MAN/AUTO
6
- OSSD1 (7) > AUTOMATIC RESTART
- OSSD2 (8) > MANUAL RESTART
OSSD1
7
Reel of external relay 1 (positive)
OSSD2
8
Reel of external relay 2 (positive)
RX1
9
PNP output of receiver photocell 1 (black)
RX2
10
PNP output of receiver photocell 2 (black)
RX3
11
PNP output of receiver photocell 3 (black)
RX4
12
PNP output of receiver photocell 4 (black)
TX1
13
TEST of emitter photocell 1 (black)
TX2
14
TEST of emitter photocell 2 (black)
TX3
15
TEST of emitter photocell 3 (black)
TX4
16
TEST of emitter photocell 4 (black)
1...,513,514,515,516,517,518,519,520,521,522 524,525,526,527,528,529,530,531,532,533,...572