BASE VERSION
MUTING VERSION
Reliability data
PL (Ref. EN ISO 13849-1)
e
e
CAT (Ref. EN 954-1)
4
4
SIL (Ref. EN IEC 61508)
3
3
SIL CL (Ref. EN IEC 62061)
3
3
PFHD – Probability of Danger Failure (1/h)
9,28E-09
8,57E-09
T1 – Life Time (Years)
20
20
MTTFD - Mean Time to Danger Failure (Years)
462
439
DC – Diagnostic Coverage (%)
96%
96,50%
SFF – Safe Failure Fraction (%)
97,20%
97,50%
HFT – Hardware Fault Tolerance
1
1
TECHNICAL DATA
mODEL SELECTION TABLE
Description
Protected
height
[mm]
Beams
N.
Respon-
se time
[msec]
Resolution
[mm]
Interaxis
[mm]
Operating
distance
[m]
Code
SG4-RB2-050-OO-E
500
2
11
519,75
500
0.5..8
957951000
SG4-RB3-080-OO-E
800
3
12
399,75
380
0.5..8
957951010
SG4-RB4-090-OO-E
900
4
12
319,75
300
0.5..6.5
957951190
SG4-RB4-120-OO-E
1200
4
12
419,75
400
0.5..8
957951020
SG4-RDB2 (passive)
500
-
-
-
500
-
957951100
SG4-RDB3 (passive)
800
-
-
-
380
-
957951110
SG4-RDB4-090 (passive)
900
-
-
-
300
-
957951170
SG4-RDB4-120 (passive)
1200
-
-
-
400
-
957951120
Description
Protected
height
[mm]
Beams
N.
Respon-
se time
[msec]
Resolution
[mm]
Interaxis
[mm]
Operating
distance
[m]
Code
SG4-RB2-050-OO-W
500
2
11
519,75
500
0.5..8
957951030
SG4-RB2L-050-OO-W
500
2
11
519,75
500
0.5..3
957951060
SG4-RB2T-050-OO-W
500
2
11
519,75
500
0.5..3
957951080
SG4-RB3-080-OO-W
800
3
12
399,75
380
0.5..8
957951040
SG4-RB3L-080-OO-W
800
3
12
399,75
380
0.5..3
957951070
SG4-RB3T-080-OO-W
800
3
12
399,75
380
0.5..3
957951090
SG4-RB4-090-OO-W
900
4
12
319,75
300
0.5..6.5
957951180
SG4-RB4-120-OO-W
1200
4
12
419,75
400
0.5..8
957951050
SG4-RDB2 (passive)
500
2
-
-
500
-
957951100
SG4-RDB2L (passive)
500
2
-
-
500
-
957951130
SG4-RDB2T (passive)
500
2
-
-
500
-
957951150
SG4-RDB3 (passive)
800
3
-
-
380
-
957951110
SG4-RDB3L (passive)
800
3
-
-
380
-
957951140
SG4-RDB3T (passive)
800
3
-
-
380
-
957951160
SG4-RDB4-090 (passive)
900
4
-
-
300
-
957951170
SG4-RDB4-120 (passive)
1200
4
-
-
400
-
957951120
base version
MUTING version
1...,504,505,506,507,508,509,510,511,512,513 515,516,517,518,519,520,521,522,523,524,...572