SG-BWS series
The SG-BWS series presents two models:
• SG-BWS-T4
: control unit with plastic
housing for DIN/OMEGA rail mounting
equipped with 16 clamps that can connect
from 1 to 4 photocell couples of the S5-ST,
SL5-ST, S300 series
with OSSD safety
outputs;
• SG-BWS-T4-MT
: control unit with plastic
housing for DIN/OMEGA rail mounting
equipped with 48 clamps that can
connect from 1 to 4 photocell couples
of the S5-ST, SL5-ST, S300 series and
contemporaneously up to 2 safety light
curtains equipped with safety outputs
activated with two 230V relay.
The SG-BWS-T4 model is
WITHOUT
MUTING FUNCTION
but presents EDM
and selectable MANUAL/AUTOMATIC
RESTART. The SG-BWS-T4-MTmodel
is provided with
DOUBLE MUTING
FUNCTION
. The control unit fits some
safety outputs controlled depending
on the status of the safety photocells
connected to the device. Adanger
condition detected by a photocell or light
curtain opens the outputs.
APPLICAtions
Extreme reliability and simplicity make
the SG-BWS control units the ideal
solution for the following applications:
• Automatic warehouses
• Machines for food packaging
• Robots
• Automatic assembling lines
• Machines for PCB production
SAFETY
CONTROL UNITS
highlights
• Two models:
- SG-BWS-T4 WITHOUT MUTING
FUNCTION
- SG-BWS-T4-MT WITH DOUBLE
MUTING FUNCTION
• Factory automation standard housing
with compact dimensions
• Possibility to connect 4 safety single-
beam and 2 safety light curtains
• PLUS functions: Single/Double muting,
Edged/triggered Override, Double
Muting Lamp, External Muting Enable
• Configurable device through dip-switches
• Satisfies the requirements of key
safety Standards, such as Category 4
of EN 954-1, SIL3 of IEC 61508, and
performance levels PL e of EN ISO
13849-1.
safety