MUTING VERSION CONNECTIONS
M12 12-pole connectors
1 = Brown = 24Vdc
2 = Blue
= 0V
3 = White
= RESET/RESTART/RESTART MODE
4 = Green
= OVERRIDE1
5 = Pink
= OSSD2
6 = Yellow = EDM
7 = Black
= MUTING ENABLE
8 = Grey
= OSSD1
9 = Red
= OVERRIDE2
10 = Violet
= LAMP INPUT
11 = Grey-Pink = OVERRIDE STATUS
12 = Red-Blue = EARTH
CONNECTIONS
M12 5-pole connectors
1 = Brown = 24Vdc
2 = White = MUTING2
3 = Blue = 0V
4 = Black = MUTING1
5 = Grey = N.C.
CON ECTIONS
ACTIVE UNIT
M12 8-pole connector
1 = White = RESET/RESTART/RESTART MODE
2 = Brown = 24Vdc
3 = Green = EDM ENABLE
4 = Yellow = EDM
5 = Grey = OSSD1
6 = Pink = OSSD2
7 = Blue = 0V
8 = Red = EARTH
BASE VERSION CONNECTIONS
ACTIVE UNITE
MAIN CONNECTOR
SECONDARY CONNECTOR
MAIN CONNECTOR
SECONDARY CONNECTOR
1...,502,503,504,505,506,507,508,509,510,511 513,514,515,516,517,518,519,520,521,522,...572