plastic - axial optics - 2 m cable
S50-PA-2-C01-NN 952001620
NPN
S50-PA-2-C01-PP 952001050
PNP
metal - axial optics - 2 m cable
S50-MA-2-C01-NN 952021510
NPN
S50-MA-2-C01-PP 952021010
PNP
plastic - axial optics - M12 connector
S50-PA-5-C01-NN 952001510
NPN
S50-PA-5-C01-PP 952001060
PNP
metal - axial optics - M12 connector
S50-MA-5-C01-NN 952021670
NPN
S50-MA-5-C01-PP 952021210
PNP
plastic - radial optics - 2 m cable
S50-PR-2-C01-NN 952001790
NPN
S50-PR-2-C01-PP 952001070
PNP
metal - radial optics - 2 m cable
S50-MR-2-C01-NN 952021610
NPN
S50-MR-2-C01-PP 952021150
PNP
plastic - radial optics - M12 connector
S50-PR-5-C01-NN 952001730
NPN
S50-PR-5-C01-PP 952001080
PNP
metal - radial optics - M12 connector
S50-MR-5-C01-NN 952021770
NPN
S50-MR-5-C01-PP 952021350
PNP
TECHNICAL NOTES
1
Limit values
2
Average life of 100.000 h with T
A
= +25 °C
3
270° single-turn trimmer
4
PVC, 4 x 0.14 mm
2
5
Compatible with quick connection systems
6
A - reverse polarity protection
B - overload and short-circuit protection on receiver outputs
S50-PA-2-C01-NN
S50-PA-2-C01-PP
S50-PA-5-C01-NN
S50-PA-5-C01-PP
S50-PR-2-C01-NN
S50-PR-2-C01-PP
S50-PR-5-C01-NN
S50-PR-5-C01-PP
S50-MA-2-C01-NN
S50-MA-2-C01-PP
S50-MA-5-C01-NN
S50-MA-5-C01-PP
S50-MR-2-C01-NN
S50-MR-2-C01-PP
S50-MR-5-C01-NN
S50-MR-5-C01-PP
Operating distance:
axial optics
0 ... 70 cm
● ● ● ●
● ● ● ●
radial optics
0 ... 40 cm
● ● ● ●
● ● ● ●
Power supply:
10 ... 30 Vdc
1
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Ripple:
≤2 Vpp
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Consumption:
≤ 35 mA
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Light emission:
infrared LED 880 nm
2
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Spot dimension:
axial optics
approx.200 mm at 60 cm
● ● ● ●
● ● ● ●
radial optics
approx.35 mm at 40 cm
● ● ● ●
● ● ● ●
Setting:
sensitivity trimmer
3
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Indicators:
yellow OUTPUT LED
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
green STABILITY LED
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Output type:
PNP, NO and NC
● ● ● ● ● ● ● ●
NPN, NO and NC
● ● ● ● ● ● ● ●
Output current:
≤ 100 mA
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Saturation voltage:
≤ 2 V
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Response time:
0.5 ms
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Switching frequency:
1 kHz
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Operating mode:
dark on NO / light on NC
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Connection:
2 m Ø 4 mm cable
4
● ●
● ●
● ●
● ●
M12 4-pole connector
5
● ●
● ●
● ●
● ●
Electrical protection:
class 2
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Mechanical protection:
IP67
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Protection devices:
A, B
6
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Housing material:
PBT
● ● ● ● ● ● ● ●
nickel plated brass
● ● ● ● ● ● ● ●
Lens material:
PMMA
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Weight:
75 g max.
● ●
● ●
25 g max.
● ●
● ●
110 g max.
● ●
● ●
60 g max.
● ●
● ●
Operating temperature:
-25 ... +55°C
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Storage temperature:
-25 ... +70°C
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Reference standard:
EN 60947-5-2
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
TECHNICAL DATA
SELECTION TABLE
All the ordering codes and information
are summarised in the last pages of
this catalogue.
DETECTION DIAGRAMS
Excess gain - axial
Detection area - axial
Excess gain - radial
Detection area - radial
Grey 18%
Grey 18%
Grey 18%
White 90%
White 90%
White 90%
Grey 18%
White 90%
Recommended operating distance
Maximum operating distance
*Only on axial optic models
II3DG*