TECHNICAL DATA
TECHNICAL NOTES
1
Limit values
2
Average life of 100.000 h with T
A
= +25 °C
3
270° single-turn trimmer
4
PVC, 4 x 0.14 mm
2
5
Compatible with quick connection systems
6
A - reverse polarity protection
B - overload and short-circuit protection on receiver outputs
S50-PA-2-E01-NN
S50-PA-2-E01-PP
S50-PA-5-E01-NN
S50-PA-5-E01-PP
S50-MA-2-E01-NN
S50-MA-2-E01-PP
S50-MA-5-E01-NN
S50-MA-5-E01-PP
Operating distance:
proximity
3 cm (OF-42-ST-20 standard fibres) ● ● ● ● ● ● ● ●
through beam
10 cm (OF-43-ST-20 standard fibres) ● ● ● ● ● ● ● ●
Power supply:
10 ... 30 Vdc
1
● ● ● ● ● ● ● ●
Ripple:
≤ 2 Vpp
● ● ● ● ● ● ● ●
Consumption:
≤ 35 mA
● ● ● ● ● ● ● ●
Light emission:
red LED 660 nm
2
● ● ● ● ● ● ● ●
Setting:
sensitivity trimmer
3
● ● ● ● ● ● ● ●
Indicators:
yellow OUTPUT LED
● ● ● ● ● ● ● ●
green STABILITY
● ● ● ● ● ● ● ●
Output type:
PNP, NO and NC
● ● ● ●
NPN, NO and NC
● ● ● ●
Output current:
≤ 100 mA
● ● ● ● ● ● ● ●
Saturation voltage:
≤ 2 V
● ● ● ● ● ● ● ●
Response time:
0.5 ms
● ● ● ● ● ● ● ●
Switching frequency:
1 kHz
● ● ● ● ● ● ● ●
Operating mode:
dark on NO / light on NC
● ● ● ● ● ● ● ●
Connection:
2 m Ø 4 mm cable
4
● ●
● ●
M12 4-pole connector
5
● ●
● ●
Electrical protection:
class 2
● ● ● ● ● ● ● ●
Mechanical protection:
IP67
● ● ● ● ● ● ● ●
Protection devices:
A, B
6
● ● ● ● ● ● ● ●
Housing material:
PBT
● ● ● ●
nickel plated brass
● ● ● ●
Fibre fixing nut material:
ABS
● ● ● ● ● ● ● ●
Weight:
75 g max.
● ●
25 g max.
● ●
110 g max.
● ●
60 g max.
● ●
Operating temperature:
-25 ... +55°C
● ● ● ● ● ● ● ●
Storage temperature:
-25 ... +70°C
● ● ● ● ● ● ● ●
Reference standard:
EN 60947-5-2
● ● ● ● ● ● ● ●
SELECTION TABLE
plastic - axial optics - 2 m cable
S50-PA-2-E01-NN 952001650
NPN
S50-PA-2-E01-PP 952001130
PNP
metal - axial optics - 2 m cable
S50-MA-2-E01-NN 952021880
NPN
S50-MA-2-E01-PP 952021040
PNP
plastic - axial optics - M12 connector
S50-PA-5-E01-NN 952001540
NPN
S50-PA-5-E01-PP 952001140
PNP
metal - axial optics - M12 connector
S50-MA-5-E01-NN 952021890
NPN
S50-MA-5-E01-PP 952021240
PNP
DETECTION DIAGRAMS
All the ordering codes and information are
summarised in the last pages of this catalogue.
Operating distance with standard fibres
* standard fibre-optics
Excess gain - proximity *
Detection area - proximity *
Excess gain - through beam *
Detection area - through beam *
Grey 18%
Grey 18%
White 90%
White 90%
Standard fibre-optics:
OF-42-ST-20 proximity
OF-43-ST-20 through beam
High efficiency fibre-optics or accessory
lenses can be used to obtain larger opera-
ting distances. Refer to
Fibre-optics
of the
General Catalogue
1...,67,68,69,70,71,72,73,74,75,76 78,79,80,81,82,83,84,85,86,87,...572