Operating distance
Resolution
Linearity
Repeatability
Ultrasonic frequency
Response time
Setting
Minimum Reading Window
Hysteresis
Temperature effect
TECHNICAL DATA
SERIES
US18
US30
Ultrasonic sensor
Power supply
Vdc
Vac
Vac/dc
Output
PNP
NPN
NPN/PNP
relay
(triac)
other
Connection
cable
connector
terminal block
Approximate dimensions (mm)
Housing material
Mechanical protection
30 ... 300 mm
2.5 ms (Fast): 1 mm
30 ms (Slow): 0.5 mm
2.5 ms (Fast): ±1 mm
30 ms (Slow): ±0.5 mm
0,5 mm
300 KHzburst, rep. rate 2.5 ms
2,5ms FAST MODE
30ms SLOW MODE
PUSH BUTTON
Teach-in
5 mm
0.7 mm
0.02% measured distance/°C
10…30
•
4…20mA / 0 ... 10 V
M12 5-poles
18x91 (axial)
18x95 (radial)
Polyester
IP67
200 ... 1000 mm
300 ... 2000 mm
0.1 % measured distance
0.25 % measured distance
1000 mm: 0.1 % of dist. (0.5 mm min.)
2000 mm: 0.1 % of dist. (1 mm min.)
1000 mm : 224 KHz
2000 mm: 174 KHz
1000 mm : 45 ms (fast), 105 ms (slow)
200 0mm : 92 ms (fast), 222 ms (slow)
PUSH BUTTON
Teach-in
10 mm
1000 mm : 2 mm
2000 mm : 3 mm
0.02% measured distance/°C
10…30
•
4…20mA / 0 ... 10 V
M12 5-poles
30 x 63.6 x 45
Polyester
IP67
OPERATING DISTANCES
DEVICES FOR MEASUREMENT