INDICATORS AND SETTING (trimmer versions)
CONNECTIONS
FIXING BRACKET
DIMENSIONS
Emitter is equipped with a
manual regulation which
lets the user change the
emission power by means of a
screwdriver.
The emission power reduction
can be particularlly useful to
lower passive reflections when
maximum operating distance
is not required.
The measurement of the object’s po-
sition or dimensions, placed inside the
sensitive area, is obtained thanks to the
0 - 10V analogue output, which supplies
a signal proportional to the number of
interrupted beams. The PNP digital ou-
tput is activated each time that a beam
is intercepted by an object; in this case,
the yellow OUT LED on the receiving
unit panel turns on. The green POWER
ON LED, always on this panel, signals
also the wrong alignment between the
emitting and receiving units as well
as the functioning outside or near the
maximum operating distance.
MODEL
L1
L2
L3
DS1-xx-010-xx
150,1
107
129,1
DS1-xx-015-xx
200,1
157
179,1
DS1-xx-030-xx
350,1
307
329,1
1 = brown = +24 Vdc
2 = white = Analogue output
3 = blue = 0 V
4 = black = Switching output
5 = grey = SYNC
1 = brown = +24 Vdc
2 = white = not used
3 = blue = 0 V
4 = black = SYNC
RECEIVER (RX)
EMITTER (TX)