CONNECTIONS
DIMENSIONS
The following operating modes can be
selected via internal dip-switches on the
receiver unit and the SET and calibra-
tion button:
• Scanning with parallel or crossed
beams
• Manual calibration or at powering on
• Absolute
1
or relative
2
measurement
• Absolute
3
or relative
4
detection
• Precise detection or with a
tolerance channel
• Light or dark output
• Sensitivity level
Notes:
1. In this mode, the analogue output is propor-
tional to the last obscured optic
2. In this mode, the analogue output is
proportional to the the total number of
obscured optics
3. In this mode, a certain object in a certain po-
sition in the sensitive area can be detected
through Teach-in. The digital ouput switches
every time the object is in this position
4. In this mode, a certain object can be de-
tected through Teach-in. The digital output
switches each time the object is inside the
sensitive area in any position
MODEL
a x b (mm)
h (mm)
DS3-SD-015
35 x 40
226
DS3-SD-030
35 x 40
376
DS3-SD-045
35 x 40
526
DS3-SD-060
35 x 40
676
DS3-LD-015
35 x 40
226
DS3-LD-030
35 x 40
376
DS3-LD-045
35 x 40
526
DS3-LD-060
35 x 40
676
1 = white
= SYNC D-
2 = brown
= +VDC
3 = green
= NOT USED
4 = yellow = PNP OUTPUT
5 = grey
= Analog OUTPUT
6 = red
= SYNC D+
7 = blue
= 0 V
8 = red
= REMOTE TEACH-IN /CALIBRATION
1 = brown = +VDC
2 = white = SYNC D+
3 = blue = 0 V
4 = black = SYNC D-
RECEIVER (RX)
EMITTER (TX)