technical data
detection DIAGRAMS
Direct measurement range
1
:
0.3 - 4 m (Y0), 0.3 - 7 m scalable (YL0)
Retroreflex measurement range
2
:
0.3 - 20.3 m (Y1), 0.3 - 100.3 m (Y2)
Linearity:
0.3% (Y0/YL0), 0.75% (Y1), 0.3% (Y2)
Temperature drift:
±0.6 mm/°C (Y0/YL0), <2mm/°C (Y1/Y2)
Warm Up:
20 min for all models
Repeatability
3
:
<5 mm (Y0 FAST)
7 mm @ 7 m (YL0), 10 mm @ 20 m (Y1), 10 mm @ 100 m (Y2)
Switching output hysteresis
3
:
5 mm (Y0/YL0), 25 mm (Y1), 40 mm (Y2)
Power supply:
15 ... 30 Vdc (limit values)
Ripple:
2 Vpp max.
Consumption:
110 mA max. @ 24 Vdc
Light emission:
red Laser 658 nm, class 2
Setting:
SET push-button
+/- push-button
Indicators
(on command panel)
:
4-digit display
yellow OUTPUT LED
green OUTPUT STATUS LED
green FAST mode LED
Indicators
(on front)
:
yellow OUTPUT LED
red ALARM LED
Output type:
2 PNP NO or 2 NPN NO
4 ... 20 mA analogue
Output current:
≤ 100 mA
Saturation voltage:
≤ 2 V
Response time:
5 ms (NORMAL) / 1 ms (FAST)
6 ms (YL0)
Switching frequency:
100 Hz (NORMAL) / 500 Hz (FAST)
85 Hz (YL0)
Timing function:
selectable between 5, 10, 20, 30 e 40 ms
Auxiliary functions:
synchronism (SYNC)
keylock
4
RS485 serial interface
Connection:
M12 8-pole connector
5
Electrical protection:
class 2
Mechanical protection:
IP67
Protection devices:
A, B
6
Housing material:
aluminium
Lens material:
glass
Weight:
330 g max.
Operating temperature:
-10 ... +50°C
Storage temperature:
-25 ... +70°C
Reference standard:
EN 60947-5-2, EN 60825-1
technical notes
1
On target 90% white to 18% grey
2
On reflector R80
3
In Normal mode with 5 ms response time
4
Active with SYNC wire connected to + Vdc for at least 1
s at powering
5
Connector can be blocked in two positions
6
A - reverse polarity protection
B - overload and short-circuit protection
Analogue output
Digital outputs
Direct measurement distance
according to object reflection degree