technical data
detection DIAGRAMS
selection table
Measurement range:
300 … 4000 mm
1
Linearity:
<1% f.s. (24 Vdc, 25 °C, with white 90% target)
Repeatability:
+/- 4 mm
Temperature drift:
< 1 mm/°C
Hysteresis:
20 mm
Power supply:
24 Vdc +/- 20%, limit values
Ripple:
2 Vpp max.
Consumption:
120 mA max (100 mA at 24V)
Light emission:
red Laser 665 nm, class 2
Spot dimension:
Ø3.5 mm at 0.3 m
Ø7 mm at 4 m
Setting:
OUT2 , OUT1
Indicators:
yellow OUTPUT 1 LED
yellow OUTPUT 2 LED
green POWER / READY LED
Output type:
2 PNP or NPN outputs
1 PNP or NPN alarm output (only S81...M)
1 analogue 0-10 V output (only S81...Y)
Output current:
100 mA max.
Response time:
5 ms
Switching frequency:
80 Hz
Connections:
5-pole M12 connector
Electrical protection:
class 2
Mechanical protection:
IP67
Protection devices:
A, B
2
Housing material:
ABS
Lens material:
PMMA
Weight:
92 g max.
Operating temperature:
-10 … 50 °C
Storage temperature:
-20 … 70 °C
Reference standard:
EN 60947-5-2, EN 60825-11
technical notes
1
On target 90% white to 18% grey
6
A - reverse polarity protection
B - overload and short-circuit protection
Analogue output
Digital outputs
White/Black difference
Model
Analogue output
0-10V
Scalable
0-10V Analogue output
Alarm output
Switching outputs
2 NPN
2 PNP
Switching outputs
S81-PL-5-M03-NNC
S81-PL-5-M03-PPC
S81-PL-5-Y03-NNV
S81-PL-5-Y03-PPV
S81-PL-5-Y03-PPVK