technical data
Models with discrete output
Models with analogue ouput
Operating distance (typical values):
30 … 300 mm
Power supply:
10 … 30 Vdc (limit values), polarity inversion protection
Ripple:
≤2 Vpp
Consumption:
65 mA max., 40 mA typical at 25 Vdc
Output type:
NPN and PNP
0…10 Vdc or 4…20 mA
Output current:
100 mA max., short-circuit protection
Saturation voltage:
PNP < 1.2 V at 10 mA, < 1.6 V at 100 mA
NPN < 200 mV at 10 mA, < 600 mV at 100 mA
Load resistance:
voltage output: 2.5 kΏ min.
current output: 1 kΏ max.
Response time:
5 ms
2.5 ms (black wire at 0-2 Vdc or unconnected)
30 ms (black wire at 5-30 Vdc)
Switching frequency:
100 Hz
200 Hz (black wire at 0-2 Vdc or unconnected)
16 Hz (black wire at 5-30 Vdc)
Delay at powering:
300 ms
Indicators:
yellow-green bi-coloured OUTPUT LED
red POWER LED
Setting:
Teach-in or remote input
Ultrasonic emission frequency:
300 KHz, repeated each 2.5 ms
Temperature drift:
minor than 1.7 % at detection distance
Repeatability:
0.5 mm
Minimum detection window:
5 mm
Hysteresis:
0.7 mm
Resolution *:
±1 mm with 2.5 ms response time
±0.5 mm with 30 ms response time
Minimum detection window dimension:
5 mm
Operating temperature:
-25 … 55 °C
Storage temperature:
-25 … 70 °C
Electrical protection:
Class 2
Housing material:
Thermoplastic polyester
Mechanical protection:
IP67
Connections:
M12 5-pole connector
Weight:
25 g
Standard reference:
EN 60068-2-6, EN 60068-2-27
detection DIAGRAMS
Beam - distance variation
(typical values)
2.25mm bar
8 mm bar
50x50 mm target
Maximum target inclination
(models with discrete output)
Aluminium target
used: 50x50 mm
Maximum target inclination
(models with analogue output)
Aluminium target
used: 50x50 mm
* with 50x50 mm aluminium target at 22°C and constant operating conditions
1...,331,332,333,334,335,336,337,338,339,340 342,343,344,345,346,347,348,349,350,351,...572